1.
Micromachines (Basel) ; 13(12)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36557559

RESUMO

This paper presents a novel bimorph Piezoelectric Micromachined Ultrasonic Transducer (PMUT) fabricated with 8-inch standard CMOS-compatible processes. The bimorph structure consists of two layers of 20% scandium-doped aluminum nitride (Sc0.2Al0.8N) thin films, which are sandwiched among three molybdenum (Mo) layers. All three Mo layers are segmented to form the outer ring and inner plate electrodes. Both top and bottom electrodes on the outer ring are electrically linked to the center inner plate electrodes. Likewise, the top and bottom center plate electrodes are electrically connected to the outer ring in the same fashion. This electrical configuration maximizes the effective area of the given PMUT design and improves efficiency during the electromechanical coupling process. In addition, the proposed bimorph structure further simplifies the device's electrical layout with only two-terminal connections as reported in many conventional unimorph PMUTs. The mechanical and acoustic measurements are conducted to verify the device's performance improvement. The dynamic mechanical displacement and acoustic output under a low driving voltage (1 Vpp) are more than twice that reported from conventional unimorph devices with a similar resonant frequency. Moreover, the pulse-echo experiments indicate an improved receiving voltage of 10 mV in comparison with the unimorph counterpart (4.8 mV). The validation of device advancement in the electromechanical coupling effect by using highly doped ScAlN thin film, the realization of the proposed bimorph PMUT on an 8-inch wafer paves the path to production of next generation, high-performance piezoelectric MEMS.

2.
Micromachines (Basel) ; 13(11)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36422408

RESUMO

Compared to conventional ultrasonic flowmeters using multiple transducers, this paper reports, for the first time, an airflow volumetric flowmeter using a signal PMUT array to measure the flow rate in a rectangular pipe. The PMUT around 200 kHz is selected to fit the system requirements. All PMUT elements on this single array are then electrically grouped into transmitter and receiver. In order to minimize the crosstalk signal between transmitter and receiver, a phase shift signal is applied at the transmitter to reduce the amplitude of the crosstalk signal by 87.8%, hence, the resultant high sensing resolution. Based on the analog signal extracted from the single PMUT array, a complete flow sensing system is built by using the cross-correlation method and cosine interpolation, whereby the change in flow rate is reflected by the time of flight difference (dTof) recorded at the receiver. Meanwhile, the acoustic path self-calibration is realized by using multiple echoes. Compared with the previously reported MEMS flowmeters with dual or multiple PMUT devices, this paper proposes a single PMUT array flow sensing system, which is able to measure the flow rate changes up to 4 m3/h. With the implementation of a single device, the problem of ultrasound device/reflector misalignment during system setup is completely eradicated.

3.
Micromachines (Basel) ; 13(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36363962

RESUMO

Piezoelectric micromachined ultrasonic transducers (PMUTs) have been widely applied in distance sensing. However, the sensing distance of currently reported miniaturized ultrasonic sensors (e.g., PMUTs or CMUT) is still limited up to a certain range (e.g., ≤5 m) compared to conventional bulk ultrasonic devices. This paper reports a PMUT array design using scandium-doped aluminum nitride (AlScN) as its piezoelectric layer for an extended long-range detection purpose. To minimize air attenuation, our device is resonating at 66 kHz for a high receive sensitivity of 5.7 mV/Pa. The proposed PMUT array can generate a sound pressure level (SPL) as high as 120 dB at a distance of 10 cm without beam forming. This PMUT design is catered for a pin-to-pin replacement of the current commercial bulk ultrasonic ranging sensor and works directly with the conventional range finding system (e.g., TI PGA460). In comparison with the common bulk transducer, the size of our device is 80% smaller. With the identical ranging detection setup, the proposed PMUT array improves the system SNR by more than 5 dB even at a distance as far as 6.8 m. The result of extended sensing distance validates our miniaturized PMUT array as the optimized candidate for most ultrasonic ranging applications. With the progressive development of piezoelectric MEMS, we believe that the PMUT technology could be a game changer in future long-range sensing applications.

4.
Anal Chem ; 94(14): 5591-5598, 2022 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35348340

RESUMO

High-cost viral nucleic acid detection devices (e.g., qPCR system) are limited resources for developing counties and rural areas, leading to underdiagnosis or even pandemics of viral infectious diseases. Herein, a novel virus detection strategy is reported. Such detection method is enabled by TR512-peptide-based biorthogonal capture and enrichment of commercially available Texas red fluorophore labeled nucleic acid on the functionalized paper. The GST-TR512 fusion protein electrostatically immobilized on the paper is constructed to retain the binding affinity of TR512-peptide toward Texas red fluorophore labeled nucleic acid released in the preamplification process, then the enrichment of analytes enhances fluorescence signal for rapid detection as volume of sample filters through the paper. The method is generally applicable to different nucleic acid preamplification strategies (PCR, RAA, CRISPR) and different virus types (Hepatitis B virus (HBV), African swine fever virus (ASFV), human papillomavirus (HPV), and severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2 or 2019 nCoV)). Finally, a full-set virus detection device is developed in house to detect the presence of Hepatitis B virus (HBV) viral gene in patients' blood samples. Taken together, we first apply TR512-peptide in the signal enrichment and the novel detection strategy may offer an inexpensive, rapid, and portable solution for areas with limited access to a standard diagnosis laboratory.


Assuntos
Vírus da Febre Suína Africana , Febre Suína Africana , COVID-19 , Ácidos Nucleicos , Febre Suína Africana/diagnóstico , Vírus da Febre Suína Africana/genética , Animais , COVID-19/diagnóstico , Corantes Fluorescentes , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Peptídeos/genética , SARS-CoV-2/genética , Sensibilidade e Especificidade , Suínos